Micro Mobile Data Center Solutions

Send your Business Requirement to Multiple Vendors in one go.
1
Add Requirements
Added Requirements
“I am looking for a Micro Mobile Data Center Solutions in north America. My budget is $50,000. Looking to buy in 15 days.”
2
Select Vendors
SCHNEIDER ELECTRIC
61 Buyers Negotiating
HPE
87 Buyers Negotiating
DELL INC
88 Buyers Negotiating
3
Send Requirement
Get Vendors & Experts Response To Each Requirement Within Hours.
Requirements submitted successfully.
ops! Something went wrong. Please try again later.
Requirements from other buyers (13)
Buyer
Jackson's requirement
25/09/2023
"Vertiv vs Huawei Micro DCs report"
Like
Comment
Buyer
Tagar's requirement
03/06/2023
"Need to present the DC market "
Like
Comment
Buyer
Kathir Kumar's requirement
27/11/2022
"We have 12 Nos of chillmann rack. Need sensors and firmware for the contro panel .configuration for the web interface"
Like
Comment
Buyer
Barakat ALMAAz's requirement
01/08/2022
"have a clear vision regarding Data Center Machinery & Equipment manufacturers"
Like
Comment
Buyer
Kelopile Makabanyane's requirement
26/04/2022
"Comparison report on Vertiv vs Eaton in Data Centers"
Like
Comment
Buyer
Dimas Prakoso's requirement
06/12/2021
"Kindly need your help is it possible for us get the free report for Micro Data Center?"
Like
Comment
Buyer
Dennis Arnold's requirement
22/11/2021
"I am looking for a Micro Data Center that is fire, water and smoke resistant "
Like
Comment
Buyer
Yariad's requirement
27/10/2021
"Comparison documents"
Like
Comment
Buyer
David Zidzik's requirement
26/10/2021
"The enclosure is to be self-contained, minimum 42RU up to 47RU with built-in UPS, power distribution, air cooling unit with temperature, humidity, water leakage and smoke sensor monitoring, keypad operated door locks and system management/monitoring front panel display with keypad. 19” Industry standard equipment up to 47U high, 42U is the minimal acceptable rack height. Self-contained 19” rack fitted with built-in UPS and cooling. Dimensions: H ~2000mm x 600mm W x minimum 1000mm D PUE (full Load): 1.2 (optimal) Input Power: AC 220-240V, 50/60Hz +/-5% Installation type will be general ground installation Security: lockable front and rear door. electronic door control from local panel or remote control. Rack is to be fully supplied with front blanking plates in 1RU, 2 RU, 4RU sizes to ensure rack front is fully sealed for air flow efficiency. Adequate combinations and spares are to be supplied to infill when equipment is inserted. UPS – o Enclosure UPS rating to be supplied as specified in Goods Schedule as either:  3kVA model, or  5kVA/6kVA model. o Maximum “User” Equipment Load is to be provided as per chosen model (3kVA or 5kVA/6kVA), UPS capacity rating is to be the available power for user equipment in addition to any UPS power requirements to operate the enclosure subsystems. o UPS to be of double on-line conversion type with pure sinusoidal wave output. o Air Conditioning: Power by dedicated minimum 3kVA UPS or as rating required by cooling system Input Voltage Range: 176-276 without derating (up to 100-276 with derating) o Input Frequency Range: 40-70Hz, 50/60Hz auto selection o Power Selection: 1.0 o Installation: Rackmount, 2RMU or up to 4RMU depending on the UPS capacity requested. Power Distribution System o Installation Dimensions: Rack mount, 3RMU o Power Distribution: Mains input and UPS output, lightning protection and maintenance bypass o PDU: Managed 0RU, plugs to suit Internal Brand Servers and switches, combination minimum 1 x C20 16A, 14 x C13, 4 x C19 Outlets Cooling and Airflow Management System: o Total Cooling Capacity: minimum 3.0kW o A/C Total Air Volume: minimum 580m3/h o A/C Power Supply (Voltage): 220 – 240 VAC +/- 5% o A/C Installation: Rack-mountable, bottom of the enclosure interior, 5RMU o Environmentally friendly refrigerant Enclosure Subsystem: o Load Rating: 1500kg"
Like
Comment
Buyer
vfer's requirement
05/10/2021
"fref"
Like
Comment
Buyer
Tito's requirement
13/09/2021
"Comparison of huawei and vertiv data centers"
Like
Comment
Buyer
Mani Hariharan Iyer's requirement
12/09/2021
"Required a Data Center Comparison Report between Hauwei and Vertive solution"
Like
Comment
Buyer
Mohd Hafizhury Mason's requirement
10/11/2020
"just wanna know the comparison between Huawei and Vertiv"
Like
Comment
500+ Micro Mobile Data Center Solutions buyers negotiating “Group Buying Deal” through 360Quadrants
I agree to 360Quadrants Terms of use and privacy policy
Success
info
Error